Setup, live measurement and analysis
in one program.
DynaDAQ One recognises Dynalabs devices over USB,
manages their settings, and shows the data as live
plots and FFT. It analyses recordings with filters,
range statistics and spectra, and exports them to
CSV or MATLAB. The same app opens the SD card
recordings of the DynaDAQ-VR vibration recorder.
Live plots and FFT
C1–C2 range statistics
Butterworth LP · HP · BP filters
CSV · .mat export
Dark · Light themes
Analyze ·
A real recording taken with DynaDAQ-VR.
The impact events are selected with C1–C2;
range statistics on the right,
the range FFT below.
FEATURES
Every step of a
measurement in one app
Automatic device detection
A device plugged into USB is found on its own;
sensors and ranges are read from the device.
Several devices per session
Accelerometers, VR and GNSS share one screen
and record together into one file.
Live plots and meters
Axes separated or combined; actual, min and
max values; Freeze to hold the view.
Live and recorded FFT
Measure and Analyze share one FFT setup
and computation, so the live spectrum
matches the recording.
Filters and range statistics
RMS, mean, min, max and peak-peak over C1–C2;
zero-phase Butterworth filters.
Import and export
Opens VR SD card recordings; exports
the selected range as CSV or MATLAB .mat.
01 · SETUP
Device settings from the software
Each connected device has its own page.
Changed settings are marked, sent to the
device with Apply and reverted with Discard.
Fields that are written to the device carry
their own icon.
Device identity and status
The app reads the fitted sensors from the
serial number and shows settings only for them.
The device clock is set from the computer
on every connection.
Identity
Device name, serial, firmware
Status
Battery and storage usage
Live stream
Which sensor streams live
(Digital or Piezo on the VR)
Calibration
Coefficients stored in the device,
last calibration date
Setup ·
Recording (SD card): rate per sensor,
Trigger mode and threshold.
Configure on-device recording
For devices that record on their own,
recording is configured from the software too.
On DynaDAQ-VR you set the SD card rate per
sensor and the log mode; the app tells you
when the SD rate differs from the live stream.
Log mode
Standard (while on) · Trigger
(above a g threshold) · Timer (set time)
Storage mode
One click opens the VR as a USB drive
to copy recordings
02 · MEASURE
Live data, axis by axis or on one plot
Data starts flowing as soon as a device connects.
Set the plot window and Y scale; Freeze holds the view,
C1–C2 cursors select a range, Fit all shows everything.
Measure ·
Separated: each axis on its own plot and scale.
Live FFT
The spectrum updates while you measure
and the peak frequency shows in a meter.
Zoom the frequency axis with the mouse
or by touch.
Record writes every device in the session
into one .dqrec file.
Stop it by hand or let it end after a set
duration. Common commands have keyboard
shortcuts.
Combined view with live FFT
(zoomed to 0–650 Hz).
Example: DynaDAQ-VR digital accelerometer.
03 · ANALYZE
Work through recordings
range by range
The screens show a real recording taken
with DynaDAQ-VR: 40 seconds of 1 kHz
three-axis acceleration with a series
of impact events.
Recording list and C1–C2 statistics
Recordings are listed by date and searchable;
start, length and devices show in the side panel.
Drag on the plot to set C1–C2 and the table
updates for that range.
In range
RMS · Mean · Min · Max · Peak-peak · Δt
At cursor
Each channel’s value
Import
VR SD card recordings (.dqconf),
named by project and part
Analyze ·
recording list and a VR recording
imported from the SD card.
After filtering: the 1 g of gravity on Z
is gone and the FFT sits in the 10–300 Hz
band. The toolbar reads
“BP 10–300 Hz · no mean”.
Filters
Low-pass, high-pass and band-pass:
4th-order Butterworth, zero phase,
with a separate option to remove the mean (DC).
Statistics, FFT and export use the processed
signal, and the toolbar always shows
the active filter.
Band-pass 10–300 Hz, mean removed.
04 · EXPORT
Take the data into the tools you use
The selected C1–C2 range is written to CSV or
MATLAB .mat. With a filter on, the processed
signal is exported, so the file matches the
screen. The format adapts to Excel, MATLAB,
Python or your own reporting tool.
Format
CSV and MATLAB .mat (GNSS channels as CSV)
Range
Between C1 and C2; move the cursors
to the ends for the whole recording
Signal
Raw or processed (the Analyze filter
and mean removal apply)
Channels
All, or only those visible on the plot
Delimiter
Comma, semicolon or tab
Decimal
Point or comma, so regional Excel
opens the file directly
Time column
Seconds from start, device / local clock,
UTC, or both
Header
Column names and # info lines:
source, device, sample rate, start time
Precision
Significant digits: auto, 4, 6 or 9
Multi-device
One file per device, each with its
own start time (_acc1, _acc2 …)
Export menu:
the selected range as CSV or MATLAB .mat.
Example: a DynaDAQ-VR recording.
Choose System, Light or Dark under Setup › General;
plot colours stay readable in both.
The app runs on Windows and on Android phones
and tablets. Pick the time zone, change the
recordings folder, and check for updates
from inside the app.
Dark
Light
↔
DEVICES
On its own or all together
DynaDAQ One runs each Dynalabs device on its own.
Devices connected together are shown in sync
on one time axis and written to one recording file.
4 accelerometers
1 BPS
2 DynaDAQ-VR
in one session, at the same time
USB
Digital and piezo accelerometer
Three-axis USB accelerometer. Sensor type,
axes, range and serial are read from the
device, and calibration is stored in
the sensor.
Capacitive
8 g or 40 g model;
range selected in the software
Piezo
Fixed range (25–2000 g),
read from the sensor
Together
Up to 4 at once, each with its
own channels (X, Y, Z · X (2) …)
One piezo accelerometer: road vibration
in a vehicle and a pothole impact.
BPS only: map, position, speed,
heading, altitude and distance.
GNSS
BPS
The BPS GNSS receiver gives position,
speed, heading and altitude.
Measure follows the vehicle live on the map;
Analyze replays the recorded track on the map.
Measure
Map, fix and satellites, speed,
heading, altitude, resettable distance
Analyze
Track and playback on the map;
max speed, moving average, distance
Export
GNSS channels to CSV with a
selectable coordinate format
USB · SD
DynaDAQ-VR
Vibration recorder with digital and piezo
accelerometers depending on the model.
Watch it live over USB; it records to its
SD card when running without a computer.
The Setup, Measure and Analyze examples
on this page were taken with a VR.
USB
Live stream, Digital or Piezo
SD
Standard · Trigger · Timer logging,
copy via Storage mode,
import into Analyze
VR only: digital accelerometer
with live FFT.
IN SYNC
All together
Accelerometers, VR and BPS stream on one screen
and one time axis. Cursor, C1–C2 selection and
zoom apply to every device at once. One Record
writes all of them into one .dqrec file, so Analyze
shows vibration next to the speed and map position
of the same moment.
Accelerometer + VR + BPS: vibration, speed,
heading, altitude and map at the same moment.
ANDROID
In the field with
a phone or tablet
The DynaDAQ One Android app uses the same
Setup › Measure › Analyze flow as the desktop.
Devices connect to the phone or tablet over USB,
and measuring, recording and analysis work
without a computer.
SCREEN
Phone and tablet; bottom tabs, pinch to zoom
RECORDINGS
The same .dqrec file as the desktop,
opens on both
ANALYZE
Statistics, FFT, filters, map and playback
Tablet · Analyze:
2 accelerometers + BPS drive.
Tablet · the same recording’s
track on the map.
SYSTEM REQUIREMENTS AND DOWNLOAD
Windows or Android
Runs on the office PC and on a tablet in the field.
The values below are for comfortable use;
lower-spec hardware may also work.
Connecting devices needs USB host (OTG) support
and an OTG cable or adapter. Installing the APK
asks for permission to install from unknown sources.
Internet is only needed for the map; measuring,
recording, analysis and export work offline.
Recording size, for example: one hour of a three-axis
accelerometer at 1 kHz is about 45 MB,
about 180 MB at 4 kHz.