Vibration measurement software Windows and Android

Setup, live measurement and analysis in one program.

DynaDAQ One recognises Dynalabs devices over USB, manages their settings, and shows the data as live plots and FFT. It analyses recordings with filters, range statistics and spectra, and exports them to CSV or MATLAB. The same app opens the SD card recordings of the DynaDAQ-VR vibration recorder.

Live plots and FFT
C1–C2 range statistics
Butterworth LP · HP · BP filters
CSV · .mat export
Dark · Light themes
DynaDAQ One Analysis and FFT
Analyze · A real recording taken with DynaDAQ-VR. The impact events are selected with C1–C2; range statistics on the right, the range FFT below.
FEATURES

Every step of a
measurement in one app

Automatic device detection

A device plugged into USB is found on its own; sensors and ranges are read from the device.

Several devices per session

Accelerometers, VR and GNSS share one screen and record together into one file.

Live plots and meters

Axes separated or combined; actual, min and max values; Freeze to hold the view.

Live and recorded FFT

Measure and Analyze share one FFT setup and computation, so the live spectrum matches the recording.

Filters and range statistics

RMS, mean, min, max and peak-peak over C1–C2; zero-phase Butterworth filters.

Import and export

Opens VR SD card recordings; exports the selected range as CSV or MATLAB .mat.

01 · SETUP

Device settings from the software

Each connected device has its own page. Changed settings are marked, sent to the device with Apply and reverted with Discard. Fields that are written to the device carry their own icon.

Device identity and status

The app reads the fitted sensors from the serial number and shows settings only for them. The device clock is set from the computer on every connection.

Identity Device name, serial, firmware
Status Battery and storage usage
Live stream Which sensor streams live (Digital or Piezo on the VR)
Calibration Coefficients stored in the device, last calibration date
DynaDAQ One Setup Device
Setup · Device, example: DynaDAQ-VR (digital 40 g + piezo 200 g).
DynaDAQ One SD Card Recording Settings
Setup · Recording (SD card): rate per sensor, Trigger mode and threshold.

Configure on-device recording

For devices that record on their own, recording is configured from the software too. On DynaDAQ-VR you set the SD card rate per sensor and the log mode; the app tells you when the SD rate differs from the live stream.

Log mode Standard (while on) · Trigger (above a g threshold) · Timer (set time)
Storage mode One click opens the VR as a USB drive to copy recordings
02 · MEASURE

Live data, axis by axis or on one plot

Data starts flowing as soon as a device connects. Set the plot window and Y scale; Freeze holds the view, C1–C2 cursors select a range, Fit all shows everything.

Measure, separated channels with live FFT
Measure · Separated: each axis on its own plot and scale.

Live FFT

The spectrum updates while you measure and the peak frequency shows in a meter. Zoom the frequency axis with the mouse or by touch.

Points 1024 · 2048 · 4096 · 8192
Window Hanning · Flat-top · Rectangular
Averaging RMS, 4–32 blocks; overlap 0 / 50 / 66.7 / 75 %

Recording

Record writes every device in the session into one .dqrec file. Stop it by hand or let it end after a set duration. Common commands have keyboard shortcuts.

DynaDAQ One Combined View with Live FFT
Combined view with live FFT (zoomed to 0–650 Hz). Example: DynaDAQ-VR digital accelerometer.
03 · ANALYZE

Work through recordings
range by range

The screens show a real recording taken with DynaDAQ-VR: 40 seconds of 1 kHz three-axis acceleration with a series of impact events.

Recording list and C1–C2 statistics

Recordings are listed by date and searchable; start, length and devices show in the side panel. Drag on the plot to set C1–C2 and the table updates for that range.

In range RMS · Mean · Min · Max · Peak-peak · Δt
At cursor Each channel’s value
Import VR SD card recordings (.dqconf), named by project and part
DynaDAQ One Analyze Recording List and Statistics
Analyze · recording list and a VR recording imported from the SD card.
DynaDAQ One Analyze After Band-pass Filtering
After filtering: the 1 g of gravity on Z is gone and the FFT sits in the 10–300 Hz band. The toolbar reads “BP 10–300 Hz · no mean”.

Filters

Low-pass, high-pass and band-pass: 4th-order Butterworth, zero phase, with a separate option to remove the mean (DC). Statistics, FFT and export use the processed signal, and the toolbar always shows the active filter.

DynaDAQ One Band-pass Filter Settings
Band-pass 10–300 Hz, mean removed.
04 · EXPORT

Take the data into the tools you use

The selected C1–C2 range is written to CSV or MATLAB .mat. With a filter on, the processed signal is exported, so the file matches the screen. The format adapts to Excel, MATLAB, Python or your own reporting tool.

Format CSV and MATLAB .mat (GNSS channels as CSV)
Range Between C1 and C2; move the cursors to the ends for the whole recording
Signal Raw or processed (the Analyze filter and mean removal apply)
Channels All, or only those visible on the plot
Delimiter Comma, semicolon or tab
Decimal Point or comma, so regional Excel opens the file directly
Time column Seconds from start, device / local clock, UTC, or both
Header Column names and # info lines: source, device, sample rate, start time
Precision Significant digits: auto, 4, 6 or 9
Multi-device One file per device, each with its own start time (_acc1, _acc2 …)
DynaDAQ One CSV and MATLAB Export
Export menu: the selected range as CSV or MATLAB .mat. Example: a DynaDAQ-VR recording.
# DynaDAQ One export
# source: Project_4_Part_1.dqrec (VR Acc)
# device: Accelerometer
# sample_rate_hz: 1007.871511
# rtc_start: 2026-08-26 14:00:33.183594
time_s,X_g,Y_g,Z_g
0.123032,0.265684307,0.691476583,0.6651088
0.124024,0.267451763,0.686340928,0.667189181
0.125016,0.263515174,0.682970703,0.669346631
APPEARANCE AND PLATFORMS

Dark or light, desktop or tablet

Choose System, Light or Dark under Setup › General; plot colours stay readable in both. The app runs on Windows and on Android phones and tablets. Pick the time zone, change the recordings folder, and check for updates from inside the app.

DynaDAQ One Dark Theme DynaDAQ One Light Theme Dark Light
↔
DEVICES

On its own or all together

DynaDAQ One runs each Dynalabs device on its own. Devices connected together are shown in sync on one time axis and written to one recording file.

4 accelerometers 1 BPS 2 DynaDAQ-VR in one session, at the same time
USB

Digital and piezo accelerometer

Three-axis USB accelerometer. Sensor type, axes, range and serial are read from the device, and calibration is stored in the sensor.

Capacitive 8 g or 40 g model; range selected in the software
Piezo Fixed range (25–2000 g), read from the sensor
Together Up to 4 at once, each with its own channels (X, Y, Z · X (2) …)
DynaDAQ One Piezo Accelerometer Measurement
One piezo accelerometer: road vibration in a vehicle and a pothole impact.
DynaDAQ One BPS GNSS Measurement
BPS only: map, position, speed, heading, altitude and distance.
GNSS

BPS

The BPS GNSS receiver gives position, speed, heading and altitude. Measure follows the vehicle live on the map; Analyze replays the recorded track on the map.

Measure Map, fix and satellites, speed, heading, altitude, resettable distance
Analyze Track and playback on the map; max speed, moving average, distance
Export GNSS channels to CSV with a selectable coordinate format
USB · SD

DynaDAQ-VR

Vibration recorder with digital and piezo accelerometers depending on the model. Watch it live over USB; it records to its SD card when running without a computer. The Setup, Measure and Analyze examples on this page were taken with a VR.

USB Live stream, Digital or Piezo
SD Standard · Trigger · Timer logging, copy via Storage mode, import into Analyze
DynaDAQ-VR Digital Accelerometer with Live FFT
VR only: digital accelerometer with live FFT.
IN SYNC

All together

Accelerometers, VR and BPS stream on one screen and one time axis. Cursor, C1–C2 selection and zoom apply to every device at once. One Record writes all of them into one .dqrec file, so Analyze shows vibration next to the speed and map position of the same moment.

DynaDAQ One Accelerometer VR and BPS synchronized measurement
Accelerometer + VR + BPS: vibration, speed, heading, altitude and map at the same moment.
ANDROID

In the field with
a phone or tablet

The DynaDAQ One Android app uses the same Setup › Measure › Analyze flow as the desktop. Devices connect to the phone or tablet over USB, and measuring, recording and analysis work without a computer.

SCREEN Phone and tablet; bottom tabs, pinch to zoom
RECORDINGS The same .dqrec file as the desktop, opens on both
ANALYZE Statistics, FFT, filters, map and playback
Tablet · Analyze: 2 accelerometers + BPS drive.
Tablet · the same recording’s track on the map.
Enlarged Android screenshot
SYSTEM REQUIREMENTS AND DOWNLOAD

Windows or Android

Runs on the office PC and on a tablet in the field. The values below are for comfortable use; lower-spec hardware may also work.

MINIMUM RECOMMENDED
OS Windows 10 64-bit Windows 11 64-bit
CPU Dual-core x64 Intel Core i5 / AMD Ryzen 5
RAM 4 GB 8 GB
STORAGE 500 MB free SSD, 10 GB+ for recordings
DISPLAY 1366 × 768 1920 × 1080
USB USB 2.0 port One port per device or a USB hub

Setup needs administrator rights; the required Microsoft Visual C++ runtime is bundled and installs offline. Updates are checked from inside the app.

MINIMUM RECOMMENDED
VERSION Android 7.0 Android 11 or later
CPU Quad-core ARM Octa-core, 64-bit
RAM 3 GB 6 GB
STORAGE 300 MB free 4 GB+ for recordings
DISPLAY Phone 8-inch or larger tablet
USB USB OTG support USB-C OTG + hub

Connecting devices needs USB host (OTG) support and an OTG cable or adapter. Installing the APK asks for permission to install from unknown sources.